English中文
YGM410The display of the room

洁净房显示屏,YGM410洁净室专用温湿度显示仪洁净房显示屏

Product introduction

YGM410 was a product that could show the temperature and humidity according to the service conditions of the clean factory. It was made of ABS plastic plate and had the function of sound and light alarm. It could be installed to the wall with the 86 connection box. The product could show 2 factors of temperature and humidity at the same time. The products had the advantages of high precision, stable performance, high reliability, and easy to install.

It was widely used in clean workshop, biological medicine, food industry, laboratory and other clean space areas.




Technical index

The display range of the temperature: -99 to +999 degrees centigrade (the display resolution is 0.1; the range can be set by pressing the button within the display range, such as setting the range to 0~100 degrees centigrade)

The display range of the humidity: 0 to 100%RH (the display resolution is 0.1)

The measurement precision: 0.2%FS

Signal input: current input: 4 to 20mA

The input type of the power was 0 to 10V

Signal out: current out: 4 to 20mA, electric load no more than 500

The power output mode was 0 to 10V, and the electric load was more than 10K

(Note: when choosing the type, please pay attention to: first of all, the input signals of both sides should be the same. Both of them are 4 to 20mA, or both of them are 0 to 10V. Second, the signals of both sides must be the same. For example, if the input of both sides is 4 to 20mA, then the output must also be 4 to 20mA)

Response time: T90 no more than 10ms

Power supply: 20~28VDC

Degree of protection: IP5X

Working environment: temperature: -20 to +50 ° C, humidity: 0 to 85%RH

The storage environment: temperature: -20 to +60 degrees, humidity: 0 to 85%RH



The layout:
YGM410洁净室专用温湿度显示仪洁净房显示屏

结构图单位:mm)
YGM410洁净室专用温湿度显示仪洁净房显示屏



Model selection form

Basic unit YGM410-

1 standard products 1

Customized x

2 (temperature, humidity) input (temperature, humidity) and output 4 to 20mA 01

0 to 10V 02

Note: when you choose a customized one, some of the technical data will not be the same as the original one. Please note it when you order.

It explained: 1. the temperature and humidity should be the same. Either 4 to 20mA, or 0 to 10V;

2. the signals of both sides must be the same. For example, if the two-way signal input was 4 to 20mA, then the output must be 4 to 20mA.



Order guide

YGM410-101

Standard products

(temperature, humidity) input (temperature, humidity) and output 4 to 20mA



It is stated that the company will continuously reform the products. If there is any change in the design or the standard, I reserve the right not to inform in advance.